45 Cables de energía para media tensión | Medium voltage power cables AL VOLTALENE H COMPACT - AL RH5Z1-OL (normalizado por Endesa | Meets Endesa standards) Tensión asignada | Rated voltage: 12/20 kV, 18/30 kV Norma diseño | Design standard: UNE 211620; GSC001; DND001 Designación genérica | Generic designation: AL RH5Z1-OL AL VOLTALENE® H COMPACT AL RH5Z1-OL F ca Datos técnicos | Technical data Características dimensionales e intensidades máximas | Dimensional characteristics and maximum intensities (1)Approximate values (subject to tolerances during manufacture). (2) Maximum permissible currents in accordance with ITC-LAT 06 of the High Voltage Lines Regulation. Staggered cables in contact and shields connected to each other and to earth at both ends. For outdoor installation: 40 ºC ambient temperature (in the shade). For underground installation: 1 m depth and ground of 1.5 K.m/W thermal resistivity and 25 ºC temperature. (1) Valores aproximados (sujetos a tolerancias de fabricación). (2) Intensidades máximas admisibles de acuerdo con ITC-LAT 06 del RLAT. Cables al tresbolillo en contacto y pantallas conectadas entre sí y a tierra en ambos extremos. Para instalación al aire: 40 ºC de temperatura ambiente (a la sombra). Para instalación enterrada: 1 m de profundidad y terreno de 1,5 K.m/W de resistividad térmica y 25 ºC de temperatura. Sección Conductor Al / Pantalla Cu Conductor crosssection (Al) / Shield crosssection (Cu) (mm2) Diámetro nominal sobre aislamiento Nominal insulation Ø (1)(mm) Diámetro nominal exterior Nominal outer diameter (1) (mm) Peso Weight (1)(kg/km) Radio mínimo de curvatura Minimum bending radius (1) (mm) Intensidad máx. admisible al aire Maximum permitted current surfacemounted (2) (A) Intensidad máx. admisible directamente enterrado Maximum permitted current directly buried (2) (A) Intensidad máx. admisible bajo tubo enterrado Maximum permitted current in conduit & buried (2) (A) Intensidad máxima de cortocircuito durante 1 s Maximum short circuit current in shield during 1 s (kA) Conductor Conductor Pantalla Shield 12/20 kV 1X95* 21,2 29,0 885 435 255 205 190 8,93 2,65 1X150* 23,9 31,6 1090 474 335 260 245 14,1 2,98 1X240* 28,0 35,6 1460 534 455 345 320 22,6 3,31 1X400* 33,0 40,7 1985 611 610 445 415 37,6 3,98 1X500 36,7 44,6 2470 669 715 505 480 47,0 4,30 1X630 40,8 48,4 2930 726 830 575 545 59,2 4,81 18/30 kV 1X95* 25,6 33,3 1105 500 255 205 190 8,93 3,14 1X150* 28,3 36,0 1330 540 335 260 245 14,1 3,47 1X240* 32,4 40,0 1720 600 455 345 320 22,6 3,81 1X400* 37,4 45,1 2285 677 610 445 415 37,6 4,30 1X500 41,1 49,0 2790 735 715 505 480 47,0 4,81 1X630 45,4 53,3 3310 800 830 575 545 59,2 5,14 * Cross-sections meet Endesa standards. * Secciones normalizadas por Endesa.
RkJQdWJsaXNoZXIy MjY3Mzk=