16 Cables de energía para baja tensión | Low voltage power cables AL VOLTALENE FLAMEX CPRO (S) - AL XZ1 (S) Tensión asignada | Rated voltage: 0,6/1 kV Norma diseño | Design standard: UNE-HD 603-5X-1 Designación genérica | Generic designation: AL XZ1 (S) Structure 1. Conductor Metal: aluminium, class 2 as per IEC 60228. 2. Insulation Material: cross-linked polyethylene (XLPE) mix, type DIX 3, as per HD 603-1. Colour: natural. 3. External sheath Material: LSOH mix, type flamex DMO 1, as per UNE HD 603-5. Colour: black. Applications Low voltage halogen-free cable. Ideal for underground and surface-mounted installations. Suitable for applications on solar farms. Suitable for installation in photovoltaic systems whose voltage between conductors or between conductor and earth does not exceed 1800 Vdc. Including offgrid systems (IT). Suitable for directly buried (without duct or conduit). Connections (ITC-BT 11). Underground distribution networks (ITC-BT 07). Indoor or receiving installations (ITC-BT 20), except for the application of Afumex Class (AS) (see ITC-BT 28 and R.D. 2267/2004). Construcción 1. Conductor Metal: aluminio clase 2 de acuerdo a IEC 60228. 2. Aislamiento Material: mezcla polietileno reticulado (XLPE) tipo DIX 3 según HD 603-1. Color: natural. 3. Cubierta exterior Material: mezcla LSOH tipo flamex DMO 1, según UNE HD 603-5. Color: negro. Aplicaciones Cable de baja tensión libre de halógenos para instalaciones subterráneas e instalaciones al aire. Adecuado para instalación en sistemas fotovoltaicos cuya tensión entre conductores o entre conductor y tierra no supere los 1800 Vdc. Incluídos sistemas en isla (IT). Permitido para soterramiento directo (sin tubo o conducto). Acometidas (ITC-BT 11). Redes subterráneas de distribución (ITC-BT 07). Instalaciones interiores o receptoras (ITC-BT 20) salvo aplicación de Afumex Class (AS) (ver ITC-BT 28 y R.D. 2267/2004). Sección Cross-section (mm) Diametro conductor Conductor diameter (mm) Espesor de aislam. Insulation thickness (mm) Diámetro nom. aislam. Insulation diameter (mm) Diámetro ext. Outer diameter (mm) Radio de curv. Bend radius (mm) Peso aprox. Approx. weight (Kg/km) Intensidad de corriente al aire** Permissible current surface-mounted ** (2) Intensidad de corriente directamente enterrado** Permissible current directly buried** (2) Intensidad de corriente bajo tubo y enterrado** Permissible current in condult and buried** (3) Resist. del cond. Cond. resistance (W/km) Máx. caida de tensión cc más (90º C) Max. voltage drop dc (90 ºC) (V/(A.Km) 2 cables (A) 3 cables (A) 2 cables (A) 3 cables (A) 2 cables (A) 3 cables (A) 1 x 16 4,65 0,7 6,1 8,3 41,5 85 95 76 76 64 71 59 1,91 3,82 1 x 25 5,85 0,9 7,7 9,9 49,5 124 121 103 98 82 90 75 1,200 2,40 1 x 35 6,75 0,9 8,6 10,8 54 153 150 129 117 98 108 90 0,868 1,736 1 x 50 8,0 1 10,1 12,5 62,5 200 184 159 139 117 128 106 0,641 1,282 1 x 70 10,0 1,1 11,9 14,5 72,5 265 237 206 170 144 158 130 0,443 0,886 1 x 95 11,2 1,1 13,8 15,8 79 340 289 253 204 172 186 154 0,320 0,640 1 x 120 12,6 1,2 15,3 17,4 87 420 337 296 233 197 211 174 0,253 0,506 1 x 150 13,85 1,4 17 19,3 96,5 515 389 343 261 220 238 197 0,206 0,412 1 x 185 16,0 1,6 19,4 21,4 107 645 447 395 296 250 267 220 0,164 0,328 1 x 240 18,0 1,7 22,1 24,2 121 825 530 471 343 290 307 253 0,125 0,250 1 x 300 20,0 1,8 24,3 26,7 133,5 1035 613 547 386 326 346 286 0,100 0,200 1 x 400 22,6 2,0 27,0 30,0 150 1345 740 663 448 370 415 350 0,0778 0,156 1 x 500 26,0 2,2 30,4 33,6 252 1660 856 770 510 420 470 400 0,0605 0 ,121 1 x 630 30,0 2,4 34,8 38,6 290 2160 996 899 590 480 545 460 0,0469 0,094 * Valores sujetos a tolerancias de fabricación. ** Intensidad máxima admisible según UNE-HD 60364-5-52 (IEC 60364-5-52). (1) Considerando 2 o 3 conductores cargados tendidos en contacto al aire a temperatura ambiente de 30 ºC. Instalación tipo F, tabla B.52.13 de UNE-HD 60364-5-52 y IEC 60364-5-52 . (2) Considerando 2 o 3 conductores cargados tendidos en contacto y directamente enterrados a una profundidad de 0,7 m, temperatura del terreno 20 ºC y resistividad térmica del suelo de 2,5 K·m/W según tabla B.52.3 y table B.52.5 de UNE-HD 60364-5-52, (IEC 60364-5-52). Instalación tipo D2. Secciones superiores a 300 mm2 calculadas según IEC 60287. (3) Considerando 2 o 3 conductores unipolares cargados tendidos en contacto y enterrados bajo tubo a una profundidad de 0,7 m, temperatura del terreno 20 ºC y resistividad térmica del suelo de 2,5 K·m/W según tabla B.52.3 y tabla B.52.5 de UNE-HD 60364-5-52, (IEC 60364-552). Instalación tipo D1. Secciones superiores a 300 mm2 calculadas según IEC 60287. * Values subject to manufacturing tolerances. ** Maximum permitted current in accordance with UNE-HD 60364-5-52, (IEC 60364-5-52). (1) Refers to two or three single-core cables laid in contact with one another, surface-mounted with an ambient temperature of 30°C. Installation F, T B.52.13 (UNE-HD 60364-5-52 and IEC 60364-5-52. (2) Refers to two or three single-core cables laid in contact with one another, directly buried at a depth of 0.7m, ground temperature of 20°C and ground resistivity of 2.5 K·m/W as per table B.52.3 and table B.52.5, installation D2. Cross-sections over 300 mm2 calculated as per IEC 60287. (3) Refers to two or three single-core cables laid in contact with one another and buried in a tube at a depth of 0.7 m, ground temperature of 20 °C and ground thermal resistivity of 2.5 K·m/W as per table B.52.3 and table B.52.5, UNE-HD 60364- 60364-52 (IEC 60364-552). Installation type D1. Cross-sections over 300 mm2 calculated as per IEC 60287. Datos técnicos | Technical data Instalación al aire Surface-mounted installation Directamente enterrada Directly buried Enterrada bajo tubo Buried in conduit
RkJQdWJsaXNoZXIy MjY3Mzk=