GUÍA DE SOLUCIONES FOTOVOLTAICAS

50 Cables de energía para media tensión | Medium voltage power cables TAP AL VOLTALENE H - AL RHZ1-2OL (normalizado por Naturgy | Meets Naturgy standards) Tensión asignada | Rated voltage: 12/20 kV, 18/30 kV Norma diseño | Design standard: UNE-HD 620-10E; NATURGY ES.00137 Designación genérica | Generic designation: AL RHZ1-2OL TAP AL VOLTALENE® H - AL RHZ1-2OL F ca Cobre Copper Datos técnicos | Technical data Características dimensionales e intensidades máximas | Dimensional characteristics and maximum intensities (1)Approximate values (subject to tolerances during manufacture). (2) Maximum admissible currents in accordance with ITC-LAT 06 of the High Voltage Lines Regulation. Cables in staggered contact and shields connected to each other and to earth at both ends. For outdoor installation: 40 ºC ambient temperature (in the shade). For underground installation: 1 m depth and ground of 1.5 K.m/W thermal resistivity and 25 ºC temperature. (1) Valores aproximados (sujetos a tolerancias de fabricación). (2) Intensidades máximas admisibles de acuerdo con ITC-LAT 06 del RLAT. Cables al tresbolillo en contacto y pantallas conectadas entre sí y a tierra en ambos extremos. Para instalación al aire: 40 ºC de temperatura ambiente (a la sombra). Para instalación enterrada: 1 m de profundidad y terreno de 1,5 K.m/W de resistividad térmica y 25 ºC de temperatura. Sección Conductor Al / Pantalla Cu Conductor crosssection (Al) / Shield crosssection (Cu) (mm2) Diámetro nominal sobre aislamiento Nominal insulation Ø (1)(mm) Diámetro nominal exterior Nominal outer diameter (1) (mm) Peso Weight (1)(kg/km) Radio mínimo de curvatura Minimum bending radius (1) (mm) Intensidad máx. admisible al aire Maximum permitted current surfacemounted (2) (A) Intensidad máx. admisible directamente enterrado Maximum permitted current directly buried (2) (A) Intensidad máx. admisible bajo tubo enterrado Maximum permitted current in conduit & buried (2) (A) Intensidad máxima de cortocircuito durante 1 s Maximum short circuit current in shield during 1 s (kA) Conductor Conductor Pantalla Shield 12/20 kV 1X95 (Al)/16* 23,2 32,1 1060 482 255 205 190 8,93 2,97 1X150 (Al)/16* 25,9 35,2 1300 528 335 260 245 14,1 2,97 1X240 (Al)/16* 30,0 39,3 1665 590 455 345 320 22,6 2,97 1X400 (Al)/16 35,0 44,6 2240 669 610 445 415 37,6 2,97 1X630 (Cu)/16 42,6 52,2 7270 783 1095 715 675 90,1 2,97 18/30 kV 1X500 (Al)/16 44,1 53,8 3070 807 715 505 480 47,0 2,97 1X630 (Al)/16 48,2 57,8 3680 867 830 575 545 59,2 2,97 * Cross-sections meet Naturgy standards. * Secciones normalizadas por Naturgy.

RkJQdWJsaXNoZXIy MjY3Mzk=