51 TAP AL VOLTALENE H - AL RHZ1-2OL (normalizado por Naturgy | Meets Naturgy standards) Tensión asignada | Rated voltage: 12/20 kV, 18/30 kV Norma diseño | Design standard: UNE-HD 620-10E; NATURGY ES.00137 Designación genérica | Generic designation: AL RHZ1-2OL TAP AL VOLTALENE® H - AL RHZ1-2OL F ca Cobre Copper Tensiones | Voltages 12/20 kV 18/30 kV Tensión asignada simple Uo (kV) | Rated phase-to-neutral voltage, Uo (kV) 12 18 Tensión asignada entre fases, U (kV) | Rated phase-to-phase voltage, U (kV) 20 30 Tensión máxima entre fases, Um (kV) | Maximum phase-to-phase voltage, Um (kV) 24 36 Tensión a impulsos, Up (kV) | Maximum phase-to-phase voltage, Um (kV) 125 170 Temperatura máxima adminisble en el conductor en servicio permanente (ºC) | Maximum permitted temperature in conductor in permanent operation (°C) 90 Temperatura máxima admisible en el conductor en régimen de cortocircuito (ºC) | Maximum permitted temperature in conductor in short circuit (°C) 250 Para el cálculo de sistemas desequilibrados (componentes simétricas) los valores que figuran en negro son de secuencia directa e inversa (coincidentes para ambos casos) y en rojo son valores homopolares. Todos los valores, salvo las capacidades que son independientes de la colocación, se han obtenido considerando cables al tresbolillo en contacto y pantallas conectadas entre sí y a tierra en ambos extremos. For the calculation of unbalanced systems (symmetrical components), the values shown in black are direct and inverse sequence (coincident for both cases), and the zero-sequence values are shown in red. All values, except for capacities that are independent of placement, were obtained considering staggered cables in contact and shields connected to each other and to earth at both ends. Sección Conductor Al /Pantalla Cu Conductor crosssection (Al) / Shield cross-section (Cu) (mm2) Resistencia en corriente continua a 20 ºC Resistance in conductor at T 20 ºC) (Ω/km) Resistencia en corriente alterna a 105 ºC Resistance in alternating current at 105 ºC (Ω/km) Reactancia inductiva a 50 Hz Inductive reactance at Hz (Ω/km) Capacidad Capacity (μF/km) Resistencia homopolar Homopolar resistance Ro (Ω/km) Reactancia inductiva homopolar Inductive homopolar resistance Xo (Ω/km) Capacidad homopolar Homopolar capacity Co (μF/km) 12/20 kV 1X95 (Al)/16* 0,320 0,403 0,125 0,216 1,155 0,514 0,216 1X150 (Al)/16* 0,206 0,262 0,118 0,251 1,038 0,508 0,251 1X240 (Al)/16* 0,125 0,161 0,108 0,304 0,952 0,503 0,304 1X400 (Al)/16 0,0778 0,102 0,101 0,368 0,907 0,487 0,368 1X630 (Cu)/16 0,0283 0,0408 0,0964 0,468 0,844 0,498 0,465 18/30 kV 1X500 (Al)/16 0,0605 0,084 0,1048 0,3081 0,875 0,508 0,303 1X630 (Al)/16 0,0469 0,064 0,100 0,344 0,857 0,506 0,343 Resistencias, reactancias y capacidades | Resistors, chokes and capacitances * Secciones normalizadas por Endesa. * Cross-sections meet Endesa standards. Valores de componentes homopolares Homopolar component values Cables de energía para media tensión | Medium voltage power cables
RkJQdWJsaXNoZXIy MjY3Mzk=